Modeling the Thermal Effects of Artificial Turf on the Urban Environment

Neda Yaghoobian Mechanical and Aerospace Engineering, University of California, San Diego, La Jolla, California

Search for other papers by Neda Yaghoobian in
Current site
Google Scholar
PubMed
Close
,
Jan Kleissl Mechanical and Aerospace Engineering, University of California, San Diego, La Jolla, California

Search for other papers by Jan Kleissl in
Current site
Google Scholar
PubMed
Close
, and
E. Scott Krayenhoff Department of Geography, The University of British Columbia, Vancouver, British Columbia, Canada

Search for other papers by E. Scott Krayenhoff in
Current site
Google Scholar
PubMed
Close
Restricted access

Abstract

The effects of artificial turf (AT) on the urban canopy layer energy balance, air and surface temperatures, and building cooling loads are compared to those of other common ground surface materials (asphalt, concrete, and grass) through heat transfer modeling of radiation, convection, and conduction. The authors apply the Temperatures of Urban Facets in 3D (TUF3D) model—modified to account for latent heat fluxes—to a clear summer day at a latitude of 33° over a typical coastal suburban area in Southern California. The low albedo of artificial turf relative to the other materials under investigation results in a reduction in shortwave radiation incident on nearby building walls and an approximately equal increase in longwave radiation. Consequently, building walls remain at a relatively cool temperature that is similar to those that are adjacent to irrigated grass surfaces. Using a simple offline convection model, replacing grass ground cover with artificial turf was found to add 2.3 kW h m−2 day−1 of heat to the atmosphere, which could result in urban air temperature increases of up to 4°C. Local effects of AT on building design cooling loads were estimated. The increased canopy air temperatures with AT increase heat conduction through the building envelope and ventilation in comparison with a building near irrigated grass. However, in this temperate climate these loads are small relative to the reduction in radiative cooling load through windows. Consequently, overall building design cooling loads near AT decrease by 15%–20%. In addition, the irrigation water conservation with AT causes an embodied energy savings of 10 W h m−2 day−1. Locally, this study points to a win–win situation for AT use for urban landscaping as it results in water and energy conservation.

Corresponding author address: Jan Kleissl, Mechanical and Aerospace Engineering, University of California, San Diego, 9500 Gilman Dr. 0411, La Jolla, CA 92093-0411. Email: jkleissl@ucsd.edu

Abstract

The effects of artificial turf (AT) on the urban canopy layer energy balance, air and surface temperatures, and building cooling loads are compared to those of other common ground surface materials (asphalt, concrete, and grass) through heat transfer modeling of radiation, convection, and conduction. The authors apply the Temperatures of Urban Facets in 3D (TUF3D) model—modified to account for latent heat fluxes—to a clear summer day at a latitude of 33° over a typical coastal suburban area in Southern California. The low albedo of artificial turf relative to the other materials under investigation results in a reduction in shortwave radiation incident on nearby building walls and an approximately equal increase in longwave radiation. Consequently, building walls remain at a relatively cool temperature that is similar to those that are adjacent to irrigated grass surfaces. Using a simple offline convection model, replacing grass ground cover with artificial turf was found to add 2.3 kW h m−2 day−1 of heat to the atmosphere, which could result in urban air temperature increases of up to 4°C. Local effects of AT on building design cooling loads were estimated. The increased canopy air temperatures with AT increase heat conduction through the building envelope and ventilation in comparison with a building near irrigated grass. However, in this temperate climate these loads are small relative to the reduction in radiative cooling load through windows. Consequently, overall building design cooling loads near AT decrease by 15%–20%. In addition, the irrigation water conservation with AT causes an embodied energy savings of 10 W h m−2 day−1. Locally, this study points to a win–win situation for AT use for urban landscaping as it results in water and energy conservation.

Corresponding author address: Jan Kleissl, Mechanical and Aerospace Engineering, University of California, San Diego, 9500 Gilman Dr. 0411, La Jolla, CA 92093-0411. Email: jkleissl@ucsd.edu

Save
  • Akbari, H., and S. Konopacki, 2005: Calculating energy-saving potentials of heat-island reduction strategies. Energy Policy, 33 , 721756.

    • Search Google Scholar
    • Export Citation
  • Arnfield, A., 1990: Canyon geometry, the urban fabric and nocturnal cooling: A simulation approach. Phys. Geogr., 11 , 220239.

  • Ashdown, I., 1994: Radiosity: A Programmer’s Perspective. John Wiley & Sons, 496 pp.

  • Bonan, G. B., 2002: Ecological Climatology. Cambridge University Press, 678 pp.

  • Bornstein, R., 1987: Mean diurnal circulation and thermodynamic evolution of urban boundary layers. Modelling the Urban Boundary Layer, Amer. Meteor. Soc., 53–94.

    • Search Google Scholar
    • Export Citation
  • Bornstein, R., B. Lebassi, E. Maurer, P. Switzer, and J. E. Gonzalez, 2009: Cooling summer daytime temperatures in two urban coastal California air basins during 1948–2005: Observations and implications. Preprints, Eighth Conf. on Coastal Atmospheric and Oceanic Prediction and Processes, Phoenix, AZ, Amer. Meteor. Soc., J21.1. [Available online at http://ams.confex.com/ams/pdfpapers/146853.pdf].

    • Search Google Scholar
    • Export Citation
  • Brutsaert, W., 1982: Evaporation into the Atmosphere. D. Reidel, 299 pp.

  • California Climate Zone 7, cited. 2009: Title 24 requirements. [Available online at http://www.pge.com/includes/docs/pdfs/about/edusafety/training/pec/toolbox/arch/climate/california_climate_zone_07.pdf].

    • Search Google Scholar
    • Export Citation
  • Campbell, G. S., and J. M. Norman, 1998: An Introduction to Environmental Biophysics. Springer, 286 pp.

  • Chen, D., T. Gustavsson, and J. Borgen, 1999: The applicability of similarity theory to a road surface. Meteor. Appl., 6 , 8188.

  • Dhakal, S., and K. Hanaki, 2002: Improvement of urban thermal environment by managing heat discharge sources and surface modification in Tokyo. Energy Build., 34 , 1323.

    • Search Google Scholar
    • Export Citation
  • Energy Efficiency and Renewable Energy, cited. 2009: Residential consumption of electricity per capita per cooling degree day. [Available online at http://apps1.eere.energy.gov/states/residential.cfm/state=CA#eleccool].

    • Search Google Scholar
    • Export Citation
  • Galassi, G., and G. Bortolin, cited. 2009: New study finds artificial turf may be too hot for summer use. [Available online at http://www.synturf.org/images/UNLV-http___news.dri.edu_nr2008_Artificial_Turf_Research_091808.pdf].

    • Search Google Scholar
    • Export Citation
  • Giridharan, R., S. Ganesan, and S. Lau, 2004: Daytime urban heat island effect in high-rise and high-density residential developments in Hong Kong. Energy Build., 36 , 525534.

    • Search Google Scholar
    • Export Citation
  • Grimmond, C. S. B., and T. R. Oke, 2002: Turbulent heat fluxes in urban areas: Observations and a Local-Scale Urban Meteorological Parameterization Scheme (LUMPS). J. Appl. Meteor., 41 , 792810.

    • Search Google Scholar
    • Export Citation
  • Harman, I., J. Barlow, and S. Belcher, 2004: Scalar fluxes from urban street canyons. Part II: Model. Bound.-Layer Meteor., 113 , 387409.

    • Search Google Scholar
    • Export Citation
  • Howell, R. H., H. J. Sauer, and W. J. Coad, 1998: Principles of Heating Ventilating and Air Conditioning. American Society of Heating, Refrigerating and Air-Conditioning Engineers, 254 pp.

    • Search Google Scholar
    • Export Citation
  • Iqbal, M., 1983: An Introduction to Solar Radiation. Academic Press, 390 pp.

  • Jansson, C., E. Almkvist, and P. Jansson, 2006: Heat balance of an asphalt surface: Observations and physically-based simulations. Meteor. Appl., 13 , 203221.

    • Search Google Scholar
    • Export Citation
  • Krayenhoff, E. S., 2005: A micro-scale 3-D urban energy balance model for studying surface temperatures. M.S. thesis, Dept. of Geography, University of Western Ontario, 232 pp.

  • Krayenhoff, E. S., and J. A. Voogt, 2004: Sensitivity testing of an urban surface scheme coupled to a 1-D boundary layer model. Preprints, Fifth Conf. on the Urban Environment, Vancouver, BC, Canada, Amer. Meteor. Soc., 5.5. [Available online at http://ams.confex.com/ams/pdfpapers/80011.pdf].

    • Search Google Scholar
    • Export Citation
  • Krayenhoff, E. S., and J. A. Voogt, 2007: A microscale three-dimensional urban energy balance model for studying surface temperatures. Bound.-Layer Meteor., 123 , 433461.

    • Search Google Scholar
    • Export Citation
  • Kruger, E. L., and D. Pearlmutter, 2008: The effect of urban evaporation on building energy demand in an arid environment. Energy Build., 40 , 20902098.

    • Search Google Scholar
    • Export Citation
  • Mascart, P., J. Noilhan, and H. Giordani, 1995: A modified parameterization of flux–profile relationships in the surface layer using different roughness length values for heat and momentum. Bound.-Layer Meteor., 72 , 331344.

    • Search Google Scholar
    • Export Citation
  • Navigant Consulting, 2006: Refining estimates of water-related energy use in California. California Energy Commission Rep. CEC-500-2006-118, 95 pp.

    • Search Google Scholar
    • Export Citation
  • Oke, T. R., 1982: The energetic basis of the urban heat island. Quart. J. Roy. Meteor. Soc., 108 , 124.

  • Oke, T. R., 1987: Boundary Layer Climates. Methuen, 435 pp.

  • Oke, T. R., G. Johnson, D. Steyn, and I. Watson, 1991: Simulation of surface urban heat islands under ‘ideal’ conditions at night. Part 2: Diagnosis of causation. Bound.-Layer Meteor., 56 , 339358.

    • Search Google Scholar
    • Export Citation
  • Oliver, J. E., 2005: Encyclopedia of World Climatology. Springer, 854 pp.

  • Speight, J. G., 2005: Lange’s Handbook of Chemistry. 16th ed. McGraw-Hill, 1572 pp.

  • Venkatram, A., 2008: Improvement of short-range dispersion models to estimate the air quality impact of power plants in urban environments. California Energy Commission, PIER Energy-Related Environmental Research Program Rep. CEC-500-2007-096, 51 pp.

    • Search Google Scholar
    • Export Citation
  • Walters, A., 2005: Vegetative assessment in an urban environment. California Water Plan Update 2005. [Available online at http://www.waterplan.water.ca.gov/docs/cwpu2005/vol4/vol4-landscapewateruse-vegetativeassessmentinurbanenvironment.pdf].

    • Search Google Scholar
    • Export Citation
All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 7545 2016 134
PDF Downloads 3759 788 49