• Early, E. A., and A. Thompson, 1996: Irradiance of horizontal quartz-halogen standard lamps. J. Res. Natl. Inst. Stand Technol.,101, 141–153.

    • Crossref
    • Export Citation
  • Eppeldauer, G., 1991: Temperature monitored/controlled silicon photodiodes for standardization. Proc. SPIE,1479, 71–77.

    • Crossref
    • Export Citation
  • Evans, R. H., and H. R. Gordon, 1994: CZCS “system calibration”:A retrospective examination. J. Geophys. Res.,99, 7293–7307.

    • Crossref
    • Export Citation
  • Hooker, S. B., and W. E. Esaias, 1993: An overview of the SeaWiFS project. Eos, Trans. Amer. Geophys. Union,74, 241–246.

    • Crossref
    • Export Citation
  • ——, and J. Aiken, 1998: Calibration evaluation and radiometric testing of field radiometers with the SeaWiFS Quality Monitor (SQM). J. Atmos. Oceanic Technol.,15, 995–1007.

  • ——, C. R. McClain, and A. Holmes, 1993: Ocean color imaging: CZCS to SeaWiFS. Mar. Tech. Soc. J.,27, 3–15.

  • Johnson, B. C., S. S. Bruce, E. A. Early, J. M. Houston, T. R. O’Brian, A. Thompson, S. B. Hooker, and J. L. Mueller, 1996: The Fourth SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-4), May 1995. NASA Tech. Memo. 104566, Vol. 37, 65 pp. [Available from NASA/Goddard Space Flight Center, Greenbelt, MD 20771.].

  • McClain, C. R., W. E. Esaias, W. Barnes, B. Guenther, D. Endres, S. B. Hooker, G. Mitchell, and R. Barnes, 1992: Calibration and validation plan for SeaWiFS. NASA Tech. Memo. 104566, Vol. 3, 41 pp. [Available from NASA/Goddard Space Flight Center, Greenbelt, MD 20771.].

  • Mueller, J. L., and R. W. Austin, 1995: Ocean optics protocols for SeaWiFS validation, revision 1. NASA Tech. Memo. 104566, Vol. 25, 66 pp. [Available from NASA/Goddard Space Flight Center, Greenbelt, MD 20771.].

  • Shaw, P.-S., B. C. Johnson, S. B. Hooker, and D. Lynch, 1997: The SeaWiFS quality monitor—A portable field calibrator light source. Proc. SPIE,2963, 772–776.

    • Crossref
    • Export Citation
  • Taylor, B. N., and C. E. Kuyatt, 1994: Guidelines for evaluating and expressing the uncertainty of NIST measurement results. NIST Tech. Note 1297, 1994 ed., 20 pp. [Available from National Institute of Standards and Technology, Gaithersburg, MD 20899.].

    • Crossref
    • Export Citation
  • Walker, J. H., and A. Thompson, 1994: Improved automated current control for standard lamps. J. Res. NIST,99, 255–261.

    • Crossref
    • Export Citation
All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 191 23 0
PDF Downloads 17 7 0

Radiometric and Engineering Performance of the SeaWiFS Quality Monitor (SQM): A Portable Light Source for Field Radiometers

View More View Less
  • 1 Optical Technology Division, National Institute of Standards and Technology, Gaithersburg, Maryland
  • | 2 Laboratory for Hydrospheric Processes, NASA/Goddard Space Flight Center, Greenbelt, Maryland
  • | 3 Reyer Corporation, New Market, Maryland
Restricted access

Abstract

A portable and stable source of radiant flux, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Quality Monitor (SQM), was developed as a field instrument for use in experiments away from the calibration laboratory such as those encountered during oceanographic cruises. The SQM monitors the radiometric stability of radiance and irradiance sensors during these field experiments; a companion paper gives results acquired during the third Atlantic Meridional Transect cruise. In conjunction with laboratory calibration sources, the SQM can be used to transfer the calibration to the field experiment. Two independent lamp assemblies generate three flux levels, and the lamps are operated at constant current using active control. The exit aperture of the SQM is large and homogeneous in radiance. The SQM was designed to approximate a Lambertian radiator. An internal heater provides operational stability and decreased warmup intervals, which minimizes lamp hours. Temperature-controlled silicon photodiodes with colored-glass filters monitor the stability of the SQM, which is better than 1%. These independent monitors, which are integrated with the SQM, provide information on the flux from the SQM and can be used to normalize the output from the field radiometers during the experiment. Three reference devices, or fiducials, which are designed to mimic the optical surfaces of the field radiometers but are not functioning detector units, are used in place of the field radiometers to produce baseline monitor signals. The front surface of the fiducial is protected when not in use and kept clean during the field experiment. The monitor signals acquired using the fiducials provide additional information on the radiometric stability of the SQM. A kinematically designed mounting ring is used on both the field radiometers and the fiducials to ensure the devices being tested view the same part of the exit aperture each time they are used.

Corresponding author address: Dr. B. Carol Johnson, Optical Technology Division, National Institute of Standards and Technology, Bldg. 221, Rm. B208, Gaithersburg, MD 20899-0001.

Email: cjohnson@nist.gov

Abstract

A portable and stable source of radiant flux, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Quality Monitor (SQM), was developed as a field instrument for use in experiments away from the calibration laboratory such as those encountered during oceanographic cruises. The SQM monitors the radiometric stability of radiance and irradiance sensors during these field experiments; a companion paper gives results acquired during the third Atlantic Meridional Transect cruise. In conjunction with laboratory calibration sources, the SQM can be used to transfer the calibration to the field experiment. Two independent lamp assemblies generate three flux levels, and the lamps are operated at constant current using active control. The exit aperture of the SQM is large and homogeneous in radiance. The SQM was designed to approximate a Lambertian radiator. An internal heater provides operational stability and decreased warmup intervals, which minimizes lamp hours. Temperature-controlled silicon photodiodes with colored-glass filters monitor the stability of the SQM, which is better than 1%. These independent monitors, which are integrated with the SQM, provide information on the flux from the SQM and can be used to normalize the output from the field radiometers during the experiment. Three reference devices, or fiducials, which are designed to mimic the optical surfaces of the field radiometers but are not functioning detector units, are used in place of the field radiometers to produce baseline monitor signals. The front surface of the fiducial is protected when not in use and kept clean during the field experiment. The monitor signals acquired using the fiducials provide additional information on the radiometric stability of the SQM. A kinematically designed mounting ring is used on both the field radiometers and the fiducials to ensure the devices being tested view the same part of the exit aperture each time they are used.

Corresponding author address: Dr. B. Carol Johnson, Optical Technology Division, National Institute of Standards and Technology, Bldg. 221, Rm. B208, Gaithersburg, MD 20899-0001.