All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 186 35 1
PDF Downloads 8 0 0

Argonne Automatic, Meteorological Data Processing System

Harry MosesRadiological Physics Division, Argonne National Laboratory, Argonne, Illinois

Search for other papers by Harry Moses in
Current site
Google Scholar
PubMed
Close
and
Frank C. KulhanekRadiological Physics Division, Argonne National Laboratory, Argonne, Illinois

Search for other papers by Frank C. Kulhanek in
Current site
Google Scholar
PubMed
Close
Full access

Abstract

This paper describes a data processing system for recording automatically on paper punch tape and a teletypewriter 29 different meteorological variables measured at the Argonne National Laboratory.

The meteorological sensors are coupled to the data system either directly or through analog-to-digital converters attached to the recorders. Average values of the meteorological variables over periods of 2, 10, or 60 min are obtained by modified ball and disc integrators and pulse accumulators. Other characteristics of the data processing system and an enumeration of difficulties encountered and their solutions are discussed.

Abstract

This paper describes a data processing system for recording automatically on paper punch tape and a teletypewriter 29 different meteorological variables measured at the Argonne National Laboratory.

The meteorological sensors are coupled to the data system either directly or through analog-to-digital converters attached to the recorders. Average values of the meteorological variables over periods of 2, 10, or 60 min are obtained by modified ball and disc integrators and pulse accumulators. Other characteristics of the data processing system and an enumeration of difficulties encountered and their solutions are discussed.