A Simple Psychrometric Apparatus for Bowen Ratio Determinations

D. H. SargeantUniversity of Wisconsin, Madison

Search for other papers by D. H. Sargeant in
Current site
Google Scholar
PubMed
Close
and
C. B. TannerUniversity of Wisconsin, Madison

Search for other papers by C. B. Tanner in
Current site
Google Scholar
PubMed
Close
Full access

Abstract

A simple apparatus has been devised which automatically reverses the vertical positions of two pairs of shielded and aspirated wet- and dry-bulb diodes. Analog voltage signals proportional to the dry and wet bulb temperatures T and Tw and to the differences ΔT and ΔTw are provided. The diodes present a low source impedance, a linear response over normal ranges, a sensitivity of about 2.3 mV(°C)−1, and as used here, a time constant of about one minute. From these measurements the Bowen ratio can be determined conveniently.

Abstract

A simple apparatus has been devised which automatically reverses the vertical positions of two pairs of shielded and aspirated wet- and dry-bulb diodes. Analog voltage signals proportional to the dry and wet bulb temperatures T and Tw and to the differences ΔT and ΔTw are provided. The diodes present a low source impedance, a linear response over normal ranges, a sensitivity of about 2.3 mV(°C)−1, and as used here, a time constant of about one minute. From these measurements the Bowen ratio can be determined conveniently.