All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 173 36 2
PDF Downloads 18 13 0

The Chopped Pyrgeometer: A New Step in Pyrgeometry

Dieter LorenzInititut für Physik der Atmosphäre, Deutsche Forschungsanstalt für Luft- und Raumfahrt (DLR), German Aerospace Research Establishment, Oberpfaffenhofen, Germany

Search for other papers by Dieter Lorenz in
Current site
Google Scholar
PubMed
Close
,
Peter WendlingInititut für Physik der Atmosphäre, Deutsche Forschungsanstalt für Luft- und Raumfahrt (DLR), German Aerospace Research Establishment, Oberpfaffenhofen, Germany

Search for other papers by Peter Wendling in
Current site
Google Scholar
PubMed
Close
,
Peter BurkertSENSORLAB GmbH, Munich, Gemany

Search for other papers by Peter Burkert in
Current site
Google Scholar
PubMed
Close
,
Friedrich FerggSENSORLAB GmbH, Munich, Gemany

Search for other papers by Friedrich Fergg in
Current site
Google Scholar
PubMed
Close
, and
Günther WildgruberSENSORLAB GmbH, Munich, Gemany

Search for other papers by Günther Wildgruber in
Current site
Google Scholar
PubMed
Close
Full access

Abstract

A new type of pyrgeometer, which uses modulation of the atmospheric radiation by a mechanical chopper, has been built for the use of ground-based and airborne measurement of broadband infrared atmospheric irradiances. The instrument basically consists of two radiometers—a target radiometer and a reference radiometer—using a specially developed chopper. The reference radiometer is used to measure the radiation of the chopper that has to be known additionally to calculate the atmospheric radiation from the signal of the target radiometer. The radiometer equations take into account the nonflat spectral response. A spectral correction factor is introduced to describe the relation between the weighted irradiance at the detector and the irradiance coming from the source. One important advantage of the chopped pyrgeometer is its nonsensitivity to the temperature distribution inside the instrument as well as its fast response.

The chopped pyrgeotmter has been used during a number of airborne missions. During the Pre-EUCREX Intercomparison Campaign flown in January 1992, two Eppley pyrgeometers, two pyrgeometers of the Foot-type, and a chopped pyrgeometer were flown, in addition to other instruments on three aircraft. During a rectangular flight pattern (box) the absolute irradiance values measured by the five instruments differ by about ±10% from the average value (≈85 W m−2) of all instruments the chopped pyrgeometer indicating the smallest values throughout.

Since a detailed error budget of all instruments was not available, special emphasis was placed on relative quantities (ratios) to describe the trends measured by the various instruments along the flight tracks. It has been found that the measurements of the chopped pyrgeometer show a much better correlation to the measurement of the Foot pyrgeometers than to the Eppley instruments. A comparison of four different model calculations with the measured data of all participating instruments at ground and at three flight levels is presented.

Abstract

A new type of pyrgeometer, which uses modulation of the atmospheric radiation by a mechanical chopper, has been built for the use of ground-based and airborne measurement of broadband infrared atmospheric irradiances. The instrument basically consists of two radiometers—a target radiometer and a reference radiometer—using a specially developed chopper. The reference radiometer is used to measure the radiation of the chopper that has to be known additionally to calculate the atmospheric radiation from the signal of the target radiometer. The radiometer equations take into account the nonflat spectral response. A spectral correction factor is introduced to describe the relation between the weighted irradiance at the detector and the irradiance coming from the source. One important advantage of the chopped pyrgeometer is its nonsensitivity to the temperature distribution inside the instrument as well as its fast response.

The chopped pyrgeotmter has been used during a number of airborne missions. During the Pre-EUCREX Intercomparison Campaign flown in January 1992, two Eppley pyrgeometers, two pyrgeometers of the Foot-type, and a chopped pyrgeometer were flown, in addition to other instruments on three aircraft. During a rectangular flight pattern (box) the absolute irradiance values measured by the five instruments differ by about ±10% from the average value (≈85 W m−2) of all instruments the chopped pyrgeometer indicating the smallest values throughout.

Since a detailed error budget of all instruments was not available, special emphasis was placed on relative quantities (ratios) to describe the trends measured by the various instruments along the flight tracks. It has been found that the measurements of the chopped pyrgeometer show a much better correlation to the measurement of the Foot pyrgeometers than to the Eppley instruments. A comparison of four different model calculations with the measured data of all participating instruments at ground and at three flight levels is presented.

Save